Archive

Archive for the ‘Potable Water Tower cleaning’ Category

CBS 11 i-Team watches as my company inspects and cleans a north Texas water tower.

November 20, 2014 Leave a comment

November 7th, 2014, Ginger Allen and the CBS 11 i-Team watches as my company inspects and cleans a north Texas water tower. The tower was cleaned as a normal maintenance procedure. A light- brown dusting of sediment was removed from the interior floor before it could get deep enough to support bacteria and become a problem.   OLYMPUS DIGITAL CAMERA The tower was cleaned by a Commercial Diver who was trained at OCEAN CORP, Houston, Texas. The Diver is sealed in his own environment, then washed down with a chlorine solution. Because we specialize in the inspection and cleaning of Potable Water Storage Facilities, all of our equipment is purchased for, and only used in, potable water. This utility is doing a great job of maintaining their system. However, utility managers across the country struggle to get the funds to properly maintain their systems. The EPA is currently considering a regulation that would require all water storage facilities to be inspected and cleaned at regular intervals. This new requirement could improve the water quality for millions of Americans.

Ron Perrin Speaks to News Crew

Ron Perrin Speaks to News Crew

The EPA is taking comments on this proposed regulation until the end of the year. We have the contact information posted on our blog, or you can just take our poll at: www.cleanwatertankproject.com. The poll results will be turned in to the EPA at the end of the year.

CBS 11 I-Team Looks At What’s In Your Water Tower

 

 

Chick here to see video Video

http://launch.newsinc.com/embed.html?type=VideoPlayer/Single&widgetId=1&trackingGroup=69016&siteSection=ndn&videoId=28175822

The Written article is here:

http://dfw.cbslocal.com/2014/11/19/watertowers/http://dfw.cbslocal.com/2014/11/19/water-towers/

—–Photos taken by RPWT Office Manager Debi Wheelan

Robert Perrin on com bot talking to the diver

Robert Perrin on com bot talking to the diver

Find us on FACEBOOK  or connect with Ron on Linked-In AND PLEASE SHARE THIS POST AND THE CBS NEWS STORY WITH YOUR FRIENDS EVERYONE DESERVES TO HAVE CLEAN SAFE TAP WATER, Take the Poll at www.cleanwatertankproject.com and we can make this happen!

Advertisements

Florida Tank Inspection

April 24, 2010 Leave a comment

In August 2003 the state of Florida set a high standard for the inspection & cleaning of potable water storage tanks.  Under FDEP 62-55-350 each of the states potable water storage tanks must be inspected and cleaned at least once every five years.  The FDEP allowed a grace period until August of 2008 before any enforcement action was taken.

Ron Perrin Water Technologies offers Qualified Inspections meeting all Florida requirements for potable water tank inspections.  Using underwater cameras, ROV’s or divers we are able to inspect 100% of your facility without any disruption in service.

If your tank is out of compliance for the cleaning requirement our professional potable water divers are available to remove all sediment from your water storage tanks at competitive prices.

Call 1-888-481-1768 for a quote today!

Florida Inspection Rule:

62-555.350 Operation and Maintenance of Public Water Systems. (1) Suppliers of water shall operate and maintain their public water systems so as to comply with applicable standards in Chapter 62-550, F.A.C., and requirements in this chapter.   (2) Suppliers of water shall keep all necessary public water system components in operation and shall maintain such components in good operating condition so the components function as intended. Preventive maintenance on electrical or mechanical equipment – including exercising of auxiliary power sources, checking the calibration of finished-drinking-water meters at treatment plants, testing of air or pressure relief valves for hydropneumatic tanks, and exercising of isolation valves – shall be performed in accordance with the equipment manufacturer’s recommendations or in accordance with a written preventive maintenance program established by the supplier of water; however, in no case shall auxiliary power sources be run under load less frequently than monthly. Accumulated sludge and biogrowths shall be cleaned routinely (i.e., at least annually) from all treatment facilities that are in contact with raw, partially treated, or finished drinking water and that are not specifically designed to collect sludge or support a biogrowth; and blistering, chipped, or cracked coatings and linings on treatment or storage facilities in contact with raw, partially treated, or finished drinking water shall be rehabilitated or repaired. Finished-drinking-water storage tanks, including conventional hydropneumatic tanks with an access manhole but excluding bladder- or diaphragm-type hydropneumatic tanks without an access manhole, shall be checked at least annually to ensure that hatches are closed and screens are in place; shall be cleaned at least once every five years to remove biogrowths, calcium or iron/manganese deposits, and sludge from inside the tanks; and shall be inspected for structural and coating integrity at least once every five years by personnel under the responsible charge of a professional engineer licensed in Florida. Dead-end water mains conveying finished drinking water shall be flushed quarterly or in accordance with a written flushing program established by the supplier of water; additionally, dead-end or other water mains conveying finished water shall be flushed as necessary whenever legitimate water quality complaints are received.

Water Tower Inspector

Please visit our main web site at www.ronperrin.com

and our blogs at  www.tankdiver.us and  www.ronperrin.us

And our new Florida Blog at www.floridatankinspector.com

Potable Water Tank Cleaning

March 22, 2010 Leave a comment

Check out www.potablewatertankcleaning.com for more information about cleaning potable water storage tanks.  Cleaning potable water storage tanks & towers removes the soft sediment from the floor of the tank that can be a habitat for bacteria and other contaminates.  It is very important that all equipment be  purchase purchased for and only used in potable water.  Cross contamination is a serious threat to any water supply.  In addition to having dedicated equipment all equipment entering the tank should be washed down with a chlorine solution as recommended by the AWWA.

Diver & ROV

Diver with scuba & Back up air

Photo:  The diver is in a dry suit that completely seals him in his own environment.  No part of the divers body touches the water.  He is also wearing a mask equipped with communications and dual air supply for safety.

Since 1997 Ron Perrin Water Technologies has been serving the water utility industry.  Based in Fort Worth Texas we primarily serve Texas and the Southeastern United States.

Visit our web site at www.ronperrin.com to see more information on Potable water tank Cleaning

Link to our Potable Water Tank Cleaning Web Page

For a free quote on Potable water Tank Inspection or Tank Cleaning

call 888-481-1768Visit our other blog at  www.ronperrin.us for more information on contaminates commonly found in potable water tanks.

Our TANK CLEANING web page at www.potablewatertankcleaning.com

Sediment being removed from a potable water storage tank

Call us Toll Free 888-481-1768